| THE CONCENTRIC DESIGN |
| CENTER OF SHAFT in the 'Center of Pipe' / 'Center of Valve Seat' Application for BUTTERFLY VALVE WITH ELASTOMER LINING. |
| |
|
|
 |
Symmetric disc design ensures favorable flow characteristics and low pressure drop |
 |
Concentric shaft ensures low operating torque |
 |
Lining gives a good protection to valve body, and acts as flange gasket |
 |
Shaft penetrates the valve seat |
 |
Limited choice of seating materials (Elastomer, only) |
 |
Suitable for installation in 'Low Pressure System' |
 |
Not suitable where FIRE-SAFE or FIRE-PROOF requirement apply to the valve or valve installation method |
| |
|
| CLASSIFICATION BY CONNECTION TYPE |
| Appearance |
Type |
General Characteristics |
 |
AV-C Series AV-CWR (WAFER) |
| • |
General Applications-Shipbuilding water works, heating and ventilation, power plants, Chemical plant etc. |
| |
| • |
Valve to be installed with long bolts between the flanges at adjacent pipe without flanges on the valve. |
| |
| • |
Easy handling and light weight. |
| • |
Easy installation less bolt quantity and low cost. |
| • |
Inconvenient maintenance of adjacent pipe. |
|
 |
AV-C Series AV-CSR (SEMI-LUG) |
| • |
General Applications-Shipbuilding water works, heating and ventilation, power plants, Chemical plant etc. |
| |
| • |
Similar as wafer type except a pair of the jack bolt hole in way of upper and lower sides for easy maintenance of adjacent pipe. |
| |
| • |
Easy handling and light weight |
| • |
Less quantity of bolt and easy installation |
| • |
Keep liquid remained during repairing adjacent pipe. |
|
 |
AV-C Series AV-CLR (FULL-LUG) |
| • |
General Applications: General piping system pump outlets, tank drains, ship side's etc. |
| • |
Ring shape thread bolt hole for bolting with flange. |
| • |
Keep pressure inside during repairing adjacent one side pipe. |
| • |
Different flange shape. |
| • |
Possible damage on full face gasket. |
| • |
Hard repairing corroded bolt. |
| • |
More man-hour for installation. |
| • |
Heavy weight. |
|
 |
AV-C Series AV-CFR (FLANGE) |
| • |
General Applications-All piping system Shipside valves, ballast valves, water works, power plants etc. |
| |
| • |
Both ends with complete flange. |
| • |
Suitable to general pipe flange. |
| • |
Suitable for shipside valve in the ship. |
| • |
Heavy weight. |
| • |
Same installation as ordinary valve. |
|
|
| |
|
| |
|
 |
SCHEMAOF CONCENTRIC TYPE |
| The valve shall be a 90°turn clockwise to close, non-jamming, resilient seated valve for zero leakage service. The valve shall be torque seated designed in such a manner that the disc can not be rorated the seat without the actuator. Also this valve enables the fluid perfect shut-off regardless of the flow direction. |
| |
| OPERATIONS |
| The following operation of the valve is possible; depend on the valve location, the type of work and service of the valve to be provided. |
| • |
Manual handle lever Operation |
| • |
Manual worm gear Operation |
| • |
Single or double acting pneumatic Operation |
| • |
Hydraulic actuator Operation |
| • |
Electric motor Operation |
|
|
| |
|
|